CHAMPION HOME STANDBY 12.5KW W/ NEMA 3 TRANSFER SWITCH
$4,199.00
Description
FEATURES
- 12.5kW continuous electrical power
- 717cc Champion OHV engine, electric start and low oil pressure shut down
- Automatic 99 amp, 12 circuit outdoor transfer switch
- Champion Auto Control Module (ACM)
- All weather composite mounting pad
- All weather steel enclosure
- Natural gas (NG) or Propane (LPG) operation
- Pressurized oiling system with spin on automotive type oil filter
- 5 year limited warranty
- 100 percent reliable
- 24 volt starting system is the most powerful in the industry. Designed to assure starting at temperatures as low as -22 degrees F
- SHIPPING IS NOT INCLUDED
Click Here for a Video on Champion Standby Generators
GENERATOR SPECIFICATIONS
| kW (LPG) | 12.5 |
| kW (NG) | 11 |
| LPG Rated Load (A) | 104/52 |
| NG Rated Load (A) | 91.6/45.8 |
| Rated Voltage | 120/240 |
| Main Line CB (A) | 53 |
| Phase | 1 |
| Rotor Poles | 2 |
| Frequency | 60 Hz |
| Insulation Class | H |
| THD (%) | <5% |
| Power Factor | 1 |
| Weight (lbs/kg) | 427 lb. (193 kg) |
| Dimensions | 49.1” x 28” x 28.3″ |
| Enclosure Material | Painted Steel |
| Enclosure Base Material | Composite |
| Operating Range °F (°C) | -22° (-30°) to 104° (40°) |
ENGINE SPECIFICATIONS
| Type: Milwaukee Series | OHV Commercial V-Twin |
| Displacement (cc) | 717 |
| Engine Speed (rpm) | 3600 |
| Block Material | Alum with Cast-locked, Cast Iron Cylinder |
| Carburetor Type | 2-barrel |
| Governor Type | Mechanical |
| Ignition System | Solid State Magneto |
| Starter | 24V |
| Oil Capacity (qt/L) | 1.5/1.4 |
| Oil Cooler | Yes |
| EPA Certified | Yes |
FUEL CONSUMPTION
| Fuel Pressure Required for NG: | 5″ – 7″ w.c. |
| NG Fuel Consumption @ 50% load (m3/hr) | 3.46 |
| NG Fuel Consumption @ Full load (m3/hr) | 5.61 |
| Fuel Pressure Required for LPG: | 10″ – 12″ w.c. |
| LPG Fuel Consumption @ 50% load (l/hr) | 5.49 |
| LPG Fuel Consumption @ Full load (l/hr) | 9.78 |
| Fuel Supply Inlet (NPT) | 3/4 |
CONTROL FEATURES
| Engine Mode: ATS | Automatically starts on utility failure |
| Engine Mode: Manual | Starts unit and runs until turned off |
| Engine Mode: Off | Stops unit / controller and charger active |
| Transfer Switch Mode: Auto | Automatically transfers power on utility failure |
| Transfer Switch Mode: Off | Does not transfer power on utility failure |
| Transfer Switch Mode: Test | Tests all components without starting generator |
| Generator State Indicator | Standard |
| Programable Start Delay | Standard |
| Weekly Exercise | Automatically starts, runs for 15 min |
| Engine Starting | Crank sequence up to five attempts |
| Starter Lockout | Cannot restart for 5 sec after engine stopped |
| Low Battery Indicator | Standard |
| Battery Charger Fault Indicator | Standard |
| Engine Warm Up | 20 sec |
| Engine Cool Down | 1 min |
| Low Oil Shutdown | Standard |
| Overspeed Shutdown | Standard |
| High Engine Temp Shutdown | Standard |
| Overcrank Protection | Standard |
| Under Speed Protection | Standard |
| Over Speed Protection | Standard |
| Continuous Battery Charging | Standard |
| Hour Meter | Standard |
| Exterior Failed Start Indicator | Standard |
| Utility Voltage Monitor | Standard |
| Safety Fuse | Standard |
| Failure to Transfer Protection | Standard |
| Incorrect Wiring Protection | Standard |






Reviews