Magnum Energy MMS1012, 1000 Watts, 12 Volts, RV Marine Inverter/Charger
Detailed Description
A remote control is HIGHLY RECOMMENDED with every Magnum Inverter so that the inverter features can be modified and error codes recovered.
The MMS Series Inverter/Charger for Mobile Applications provides pure sine wave power for smaller energy needs.
A new, cost effective pure sine wave inverter/charger from Magnum Energy
The MMS Series Inverter/Charger is a pure sine wave inverter providing a cost effective solution for those with smaller power needs in mobile applications. Versatile, easy-to-use and light weight, the MMS Series provides a reliable base for your energy system.
Power Factor Corrected (PFC) Charger:
Our PFC charger is built into all of our inverter chargers. It uses less energy from a generator than a standard charger – using only 7.5 amps per 50 amps versus 12.5 amps used by standard chargers.
Safe and Reliable: The MMS Series is ETL Listed to the stringent requirements of UL/cUL 458 and CSA C22.2 #107.1-01 for mobile use.
Attractive Styling:The modern, hourglass case, paired with the die cast aluminum base combines form with functions, creating an attractive unit that uses its base as a heat sink for superior high temperature operation.
Features
You asked and Magnum listened. The MMS Series Inverter/Charger is loaded with features.
Standard transfer relay: The standard 20 amp transfer relay will pass AC power through the inverter when using shore or generator power.
Low/high battery protection: If your battery voltage reaches below 10 VDC or above 15.5 VDC, the MMS Series will automatically shut down.
Versatile Mounting Mount the ME Series on a shelf, bulkhead, or even upside down.
Fan cooled: The MMS Series is fan cooled, enabling the unit to work well in confined spaces. If the inverter does exceed its temperature limits, it will automatically shut down and then restart when it cools down.
Current overload protection:The MMS Series will automatically shut down if its output wattage is exceeded or it detects a short in the wiring saving the unit from costly damage.
Convenient switches: The MMS Series comes with an on/off front-mounted switch with an easy-to-read LED indicator.
Circuit breaker protection: This model comes with built in input and output circuit breakers for ease of installation
Battery temp sensor: The standard battery temp sensor monitors temperatures from 0 to 50C
But with ease: The MMS Series is backed by a two-year (24 month) parts and labor warranty.
Accessories and Options:
- Remote Control: The optional ME-RC and MM-RC remotes are available for the MMS Series. A four wire phone jack comes standard with the unit to connect the remote.
- Fuse Blocks
Inverter Specifications
Input battery voltage: 9 to 17 VDC
Nominal AC output voltage: 120 VAC +-5%
Output frequency and accuracy: 60 Hz +- 0.005%
Total Harmonic Distortion (THD): <5%
1 msec surge current: 38 amps AC
100 msec surge current: 21 amps AC
5 sec surge power: 1750 real watts
30 sec surge power: 1600real watts
5 min surge power: 1200 real watts
30 min surge power: 1050 real watts
Continuous power output at 25C: 1000 VA
Rated input battery current: 102 ADC
Inverter efficiency: 87%
Transfer time: 16 msecs
Search Module (with remote): 0.3 ADC
No Load (120 VAC output with remote): 1.5 ADC
Waveform: Pure Sine Wave
Charger Specifications
Continuous output at 25C: 50 ADC
Charger efficiency: 84%
Power Factor: >0.95
Input current at rated output: 7 AC amps
General Features and Capabilities
Transfer relay capability: 20 AA (input current for charging and pass through)
Battery temperature compensation: Yes, standard temp sensor (battery temp 0 to 50C)
Remote available: Yes, MM-RC, ME-RC
Internal cooling: 0 to 59 cfm variable speed
Over-current protection: Yes, with two overlapping circuits
Over-temperature protection: Yes on transformer, and MOSFETS
On/Off with status indicator: Yes, front mounted and easily accessible
Lower battery cutout: 10 VDC, adjustable with the ME-RC remote
AC output and input: Hardwire
Output circuit breaker: 12 amp switchable
Input circuit breaker: 20 AAC
Listings: ETL listed to UL/cUL 458, CSA C22.2 #107.1-01, meets KKK-A-1822 standard
Warranty: Two (2) years
Environmental Specifications
Operating temperature: -20C to 60C (-4F to 140F)
Non-operation temperature: -40C to 70C (-40F to 158F)
Operating humidity: 0 to 95% RH non condensing
Physical Specifications
Mounting: Shelf (top or bottom up) or bulkhead (vents up)
Max operating altitude: 15,000′ / 4570m
Construction: ABS plastic top and cast aluminum bottom
Dimension (HWD): 16.6" x 8.4" x 4.7" / 420 x 210 x 120 mm
Weight: 20 lb (9.1 kg)
Reviews
There are no reviews yet.