Schneider Electric Conext Battery Monitor for XW+/SW
The Conext Battery Monitor indicates hours of battery-based runtime and determines battery bank state of charge. It shares key battery bank parameters with Conext XW+ and SW inverter/chargers improving overall system performance of 24V and 48V battery banks. Detecting battery string imbalance is determined using innovative mid-point sensing technology providing time to address the issue before performance is significantly impacted. Conext Battery Monitor features built-in data logging and a local display to selectively show the voltage, current, consumed amp-hours, remaining capacity and remaining hours. The same information and battery bank data is reported by ComBox and distributed to other Conext devices such XW+ or SW inverter/chargers as well as MPPT Solar Charge Controllers, Automatic Generator Start module and System Control Panel. This is done via Xanbus network connectivity enhancing performance of the overall system. Industrial and telecom customers can integrate Conext Battery Monitor with energy management systems over Modbus RS485.
FEATURES:
- Get the most out of battery-based Conext XW+ and SW inverter/charger systems
- Clearly understand hours of available battery based autonomy
- Detect imbalance between battery-strings before it becomes an issue
- Enables State of Charge triggers for AGS module control of diesel generators
- Enables balancing of multi-battery bank systems for large clustered Conext XW+ inverter charger systems
- Remotely monitor, troubleshoot or upgrade firmware with Conext ComBox
- Built-in data logger – 10 data points every 10 mins for 10 years
- Wall-mount, DIN-rail mount, or panel mount
- RJ45 connections for XanBus network and battery signals
- Configure with front-panel buttons, Conext ComBox or RS485 Modbus
- Includes: Temperature sensor; Battery Interface (Battery Cable and CAT5 Cable) Kit w/500A Shunt
- 5 Year Warranty
ELECTRICAL /MECHANICAL CHARACTERISTICS:
SPECIFICATIONS | |
Battery Capacity Range | 20 – 10, 000 Ah |
Supply Voltage | 18-66 VDC |
Supply Current (backlight off, logging-disabled)) | 80 mA @ VIN=48 VDC, 150 mA @ VIN=24 VDC |
Input Voltage Range | 0-70 VDC |
Input Current Range | -9999 – +9999 A |
IP rating / location | IP20/indoor only |
Operating Temperature Range | -20 to 50ºC (-4ºF to 122ºF) |
Network | Protocol: Xanbus / Connectors: RJ45 |
Safety | CSA 107.1, UL 458 4th Ed |