SOLAREDGE POWER OPTIMIZER P320-P505 FOR HIGH POWER 60 CELL MODULE

$71.95$92.00

Pay Over Time with Bread Pay™
 
SKU: N/A Category: Tags: ,

Description

DISCONTINUED PRODUCT

SolarEdge  Power Optimizer – High Power 60 Cell Modules

The SolarEdge Power Optimizer is a DC/DC converter which is connected by installers to each PV module, replacing the traditional solar junction box. The SolarEdge power optimizers increase energy output from PV systems by constantly tracking the maximum power point (MPPT) of each module individually. Furthermore, the power optimizers monitor the performance of each module and communicate performance data to the SolarEdge monitoring portal for enhanced, cost-effective module-level maintenance. Each power optimizer is equipped with the unique SafeDC™ feature which automatically shuts down modules’ DC voltage whenever the inverter or grid power is shut down. The MPPT per module allows for flexible installation design with multiple orientations, tilts and module types in the same string. When working with SolarEdge Inverters, SolarEdge power optimizers automatically maintain a fixed string voltage, allowing installers even greater flexibility with longer strings and strings of different lengths in order to design optimal PV systems. The SolarEdge power optimizers are compatible with c-Si and thin-film modules and have a 25 year warranty.

FEATURES:

  • Ease of installation – simply clip the power optimizer to the module frame or attach to the rail with a single screw
  • Only requires equipment grounding – with a single star washer (included) between the optimizer and the racking (grounding lugs not needed)
  • For Single Phase Inverters
  • Connects one module per optimizer
  • Up to 25% more harvested energy from your PV system
  • Per-module Maximum Power Point Tracking (MPPT)
  • Superior efficiency (99.5% peak efficiency, 98.8% weighted efficiency)
  • Mitigates all types of modules mismatch-loss, from manufacturing tolerance to partial shading
  • Allows for parallel strings of different lengths or orientations
  • Designed for extreme environmental conditions
  • Advanced, real-time performance measurement
  • Automatic module DC voltage shut-down for installer and firefighter safety. Each optimizer has an internal temperature sensor which detects if it gets over 185 degrees °F – and they shut down, if reached.
  • 25 Year Warranty

ELECTRICAL CHARACTERISTICS:

SPECIFICATIONS P300 Optimizer
(60-cell modules)
P320 Optimizer
(high power
60-cell modules)
P400 Optimizer (72/96-cell modules)
Rated Input DC Power 300W 320W 400W
Absolute Max Input Voltage 48Vdc 48Vdc 80Vdc
MPPT Operating Range 8-48 Vdc 8-48 Vdc 8-80 Vdc
Max Short Circuit Current (Isc) 10A 11A 10A
Max DC Input Current 12.5A 13.75A 12.5A
Max/Weighted Efficiency 99.5% / 98.8%
Max Output Current 15A
Max Output Voltage 60Vdc 60Vdc 85Vdc
Safety Output Voltage per Optimizer (during standby) 1 Vdc
INSTALLATION SPECIFICATIONS P300 Optimizer
(60-cell modules)
P320 Optimizer
(High Power
60-cell modules)
P400 Optimizer (72/96-cell modules)
Max Allowed System Voltage 1000 Vdc
Input Connector (Modules) MC4 compatible
Output Wire Type/Connector (Optimizers) PV Wire / MC4
Output Wire Length 3 ft (.95 m) 3 ft (.95 m) 3.9 ft (1.2 m)
Operating Temp Range -40 to +85°C / -40 to +185°F
Max/Weighted Efficiency 99.5% / 98.8%
Relative Humidity 0 – 100%
Protection Rating IP65 / NEMA4
Optimizer String Length (Min- Max) 8 – 25
Max Power per String 5250W

**NOTE: P300/P400 optimizers can be combined in one string. P600/P700 optimizers can be combined in one string. It is not allowed, however, to mix P600/P700 optimizers with P300/P400 optimizers in one string.

Additional information

SIZE

, , ,

Reviews

There are no reviews yet.

Be the first to review “SOLAREDGE POWER OPTIMIZER P320-P505 FOR HIGH POWER 60 CELL MODULE”

Your email address will not be published. Required fields are marked *